- Heating Elements
- Cartridge Heater
- Tubular Heater
- Finned Air Heater
- Flange Immersion Heater
- Coil Heater
- Sealed Nozzle Heater
- Industrial Band Heater
- Cast In Heater
- Silicone Rubber Heater
- Flexible Ceramic Pad Heater
- Infrared Heaters
- IR Quartz Heating Lamp
- Infrared Quartz Heat Emitter
- Ceramic Infrared Heater
- Heater Accessory
- Thermocouple
- Ceramic Terminal Connector
- Silicone Rubber Plug
- Electric Cable
- Heating Alloy Wire
Ceramic Infrared Heater
Ceramic Infrared Heaters are efficient, robust heaters which provide long wave infrared radiation. They are used in a diverse range of industrial processes such as heaters for thermoforming, and as heaters for paint curing, printing and drying. Most plastics and many other materials absorb infrared wave best in this range. Ceramic infrared heating elements are also used very effectively in infrared outdoor heaters and infrared saunas, which makes the ceramic heater to be the most efficient infrared radiant emitter on the market.
Features:
1). Nickel chrome resistance wire(NiCr20/80)
2). K-type thermocouple mounted internally in center heater, J-type is also available.
3). Voltage: 110V 120V 220V 230V 240V standard
4). Useful wavelength range: 2-10 microns
5). Operating temperature is 300°C to 800°C (572°F - 1472°F)
6). Average Operating Life-Up to 20,000 hrs depending on conditions.
7). Recommended radiation distance from heater is 100 mm to 250 mm.
8). Heating alone or together.
9). It is heated up to 800°C, put in cold water repeatly for ten times and no cracking.
Specifications
Dimension (mm) |
Wattage (W) |
Type |
Color |
245x80 (240x80) |
150~1000 |
Curved/Flat/Hollow |
White/Black/Yellow |
245x60 (240x60) |
150~1000 |
Curved/Flat/Hollow |
White/Black/Yellow |
122x60 (120x60) |
125~500 |
Curved/Flat/Hollow |
White/Black/Yellow |
122x122 (120x120) |
150~750 |
Curved/Flat/Hollow |
White/Black/Yellow |
60x60 |
125~250 |
Curved/Flat/Hollow |
White/Black/Yellow |
TYPE - 1 |
245mm x 60mm (240mm x 60mm) |
|||
Wattage (W) |
250 |
400 |
650 |
1000 |
Density (KW/㎡) |
16.0 |
25.6 |
41.6 |
64.0 |
Operating Temp. |
400°C |
500°C |
620°C |
720°C |
Wavelength |
2um ~ 10um |
|||
TYPE - 2 |
122mmx 60mm (120mm x 60mm) |
|||
Wattage (W) |
125 |
200 |
325 |
500 |
Density (KW/㎡) |
16.0 |
25.6 |
41.6 |
64.0 |
Operating Temp. |
400°C |
500°C |
620°C |
720°C |
Wavelength |
2um ~ 10um |
|||
TYPE - 3 |
122mmx 122mm (120mm x 120mm) |
|||
Wattage (W) |
250 |
400 |
650 |
750 |
Density (KW/㎡) |
16.0 |
25.6 |
41.6 |
64.0 |
Operating Temp. |
400°C |
500°C |
620°C |
720°C |
Wavelength |
2um ~ 10um |
|||
TYPE - 4 |
60mm x 60mm |
|||
Wattage (W) |
60 |
100 |
200 |
250 |
Density (KW/㎡) |
16.0 |
25.6 |
41.6 |
64.0 |
Operating Temp. |
400°C |
500°C |
620°C |
720°C |
Wavelength |
2um ~ 10um |
Drawings as below:
Application & Installation
Drying, Sauna, Vacuum forming, Solidify, Medical treatment sanitation, BGA rework station, Eelectron, Textile, Light industry, Chemical, Medicine, Food industry.